PUROS Compact
Max. flow rate: 6-8 L/min
Dimensions (WxDxH): 90x40x74 cm
Weight: 88 kg
PUROS
Max. flow rate: 16 L/min
Dimensions (WxDxH): 66x60x165
Weight: 185 kg


Pre-treatment
Every water treatment process begins with the prefiltration of suspended solids. PUROS uses an activated carbon filter for this purpose to additionally adsorb free chlorine, which is regularly used by water utilities to disinfect drinking water supply lines.

STAGE 1:
Size: 20” x 2.5” - Purpose: Filtration of suspended solids up to 10 µm and free chlorine - Replacement interval: at least every 6 months or when pressure drop exceeds 0.4 bar.
There are contaminants, such as corrosion by-products from municipal water supply networks, that require special pretreatment before they can be filtered out. The second-stage oxidation filter removes all metals (iron, copper, etc.) as well as a wide variety of other contaminants. The feedwater becomes crystal clear with very low turbidity.
STAGE 2:
Size: 20” x 4.5”, Big Blue - Purpose: Oxidation and removal of contaminants such as heavy metals - Replacement interval: Every 3 months or after a maximum water flow of 200 m³.
Specific Changes to Water Properties
After pre-treatment, the water is directed to the back of PUROS, where special treatments optimize the water for use in waterjet systems.

Effective water softening is of great importance. To achieve this, PUROS uses a special catalyst that converts calcium and magnesium hardness into insoluble microcrystals of calcium carbonate. Carbon dioxide is released as a byproduct of this process.
We have been using this solution in our water treatment systems since 2010, after commercially available water softeners caused problems. This approach prevents scale buildup in the waterjet cutting system without the need for a standard water softener, which is prone to malfunctions.
The carbon dioxide produced during this process is removed by a microbubble deaerator.

Preventing Silicate Crystallization
Silicates cause the formation of crystals and sludge in high-pressure pumps. These residues result in short service life for seals and nozzles.
With the addition of another catalyst, the silicate anions (negatively charged) become positively charged through an exothermic reaction. Due to the change in surface charge from negative to positive, the silicate is no longer able to form crystals and sludge.
STAGE 3:
Size: 8" x 35", black pressure vessel combined with a microbubble aerator - Purpose: Two different catalysts alter the properties of the water using the fluidized bed process. Replacement interval for the reaction vessel containing catalysts: 3 years.
Prevention of cavitation in high-pressure pumps
All tap water has a certain carbon dioxide content. Due to emissions from traffic, industry, and heating, water in urban areas generally has a higher carbon dioxide content than water in rural areas.
The following applies specifically to high-pressure pumps:
The lower the carbon dioxide content of the cooling water, the less wear on the components of high-pressure pumps caused by cavitation.

After preliminary separation using a microbubble deaerator, the carbon dioxide content is completely removed in the SICO filter. The SICO filter contains bead-shaped adsorbent that binds the carbon dioxide and silicates. Weekly backwashing removes the byproducts of this reaction.
STAGE 4:
Size: 10” x 54”, green process tank with a backwash valve at the top - Purpose: The adsorbent removes carbon dioxide and silicates - The consumption of adsorbent is compensated for by refilling every 3 months.
Post-cleaning, Disinfection, and Monitoring
After treatment, the water is returned to the front of the PUROS, where any remaining reaction byproducts are completely filtered out. If the cutting system is not used for an extended period, there is a risk of bacterial contamination of the water in the filter housings. The nanofilter used disinfects the water and provides reliable protection.

STAGE 5:
Size: 20” x 4.5”, Big Blue - Purpose: Removal of process contaminants and bacteria - Replacement interval: every 3 months or when water flow reaches a maximum of 200 m³.
To prevent contamination, it is essential to adhere to the replacement intervals for the Big-Blue working filters. If the filters are not replaced in a timely manner, contaminants will break through, causing malfunctions in the high-pressure pump.
The last filter acts as a safety filter. The filter blocks the flow of water if the water is still too heavily contaminated. This occurs when the dirt-holding capacity of the upstream filters is exceeded. If the safety filter blocks the flow of water, the upstream working filters in the Big Blue housings should also be replaced. This ensures optimal protection for the high-pressure pump.
STAGE 6:
Size: 10” x 2.5”, absolute membrane filter - Purpose: Police filter - No specified replacement interval. The police filter is replaced when it blocks water flow due to contamination or when the pressure drop becomes too high (>0.4 bar).